eprintid: 17893 rev_number: 8 eprint_status: archive userid: 2 dir: disk0/00/01/78/93 datestamp: 2025-12-15 23:30:08 lastmod: 2025-12-15 23:30:09 status_changed: 2025-12-15 23:30:08 type: article metadata_visibility: show creators_name: Agajie, Takele Ferede creators_name: Fopah-Lele, Armand creators_name: Ali, Ahmed creators_name: Amoussou, Isaac creators_name: Khan, Baseem creators_name: Elsisi, Mahmoud creators_name: Mahela, Om Prakash creators_name: Álvarez, Roberto Marcelo creators_name: Tanyi, Emmanuel creators_id: creators_id: creators_id: creators_id: creators_id: creators_id: creators_id: creators_id: roberto.alvarez@uneatlantico.es creators_id: title: Optimal Sizing and Power System Control of Hybrid Solar PV-Biogas Generator with Energy Storage System Power Plant ispublished: pub subjects: uneat_eng divisions: uneatlantico_produccion_cientifica divisions: uninimx_produccion_cientifica full_text_status: public keywords: solar PV; energy storage system; hybrid renewable energy sources; superconducting magnetic energy storage abstract: In this paper, the electrical parameters of a hybrid power system made of hybrid renewable energy sources (HRES) generation are primarily discussed. The main components of HRES with energy storage (ES) systems are the resources coordinated with multiple photovoltaic (PV) cell units, a biogas generator, and multiple ES systems, including superconducting magnetic energy storage (SMES) and pumped hydro energy storage (PHES). The performance characteristics of the HRES are determined by the constant power generation from various sources, as well as the shifting load perturbations. Constant power generation from a variety of sources, as well as shifting load perturbations, dictate the HRES’s performance characteristics. As a result of the fluctuating load demand, there will be steady generation but also fluctuating frequency and power. A suitable control strategy is therefore needed to overcome the frequency and power deviations under the aforementioned load demand and generation conditions. An integration in the environment of fractional order (FO) calculus for proportion-al-integral-derivative (PID) controllers and fuzzy controllers, referred to as FO-Fuzzy-PID controllers, tuned with the opposition-based whale optimization algorithm (OWOA), and compared with QOHSA, TBLOA, and PSO has been proposed to control the frequency deviation and power deviations in each power generation unites. The results of the frequency deviation obtained by using FO-fuzzy-PID controllers with OWOA tuned are 1.05%, 2.01%, and 2.73% lower than when QOHSA, TBLOA, and PSO have been used to tune, respectively. Through this analysis, the algorithm’s efficiency is determined. Sensitivity studies are also carried out to demonstrate the robustness of the technique under consideration in relation to changes in the sizes of the HRES and ES system parameters. date: 2023-03 publication: Sustainability volume: 15 number: 7 pagerange: 5739 id_number: doi:10.3390/su15075739 refereed: TRUE issn: 2071-1050 official_url: http://doi.org/10.3390/su15075739 access: open language: en citation: Artículo Materias > Ingeniería Universidad Europea del Atlántico > Investigación > Artículos y libros Universidad Internacional Iberoamericana México > Investigación > Producción Científica Abierto Inglés In this paper, the electrical parameters of a hybrid power system made of hybrid renewable energy sources (HRES) generation are primarily discussed. The main components of HRES with energy storage (ES) systems are the resources coordinated with multiple photovoltaic (PV) cell units, a biogas generator, and multiple ES systems, including superconducting magnetic energy storage (SMES) and pumped hydro energy storage (PHES). The performance characteristics of the HRES are determined by the constant power generation from various sources, as well as the shifting load perturbations. Constant power generation from a variety of sources, as well as shifting load perturbations, dictate the HRES’s performance characteristics. As a result of the fluctuating load demand, there will be steady generation but also fluctuating frequency and power. A suitable control strategy is therefore needed to overcome the frequency and power deviations under the aforementioned load demand and generation conditions. An integration in the environment of fractional order (FO) calculus for proportion-al-integral-derivative (PID) controllers and fuzzy controllers, referred to as FO-Fuzzy-PID controllers, tuned with the opposition-based whale optimization algorithm (OWOA), and compared with QOHSA, TBLOA, and PSO has been proposed to control the frequency deviation and power deviations in each power generation unites. The results of the frequency deviation obtained by using FO-fuzzy-PID controllers with OWOA tuned are 1.05%, 2.01%, and 2.73% lower than when QOHSA, TBLOA, and PSO have been used to tune, respectively. Through this analysis, the algorithm’s efficiency is determined. Sensitivity studies are also carried out to demonstrate the robustness of the technique under consideration in relation to changes in the sizes of the HRES and ES system parameters. metadata Agajie, Takele Ferede; Fopah-Lele, Armand; Ali, Ahmed; Amoussou, Isaac; Khan, Baseem; Elsisi, Mahmoud; Mahela, Om Prakash; Álvarez, Roberto Marcelo y Tanyi, Emmanuel mail SIN ESPECIFICAR, SIN ESPECIFICAR, SIN ESPECIFICAR, SIN ESPECIFICAR, SIN ESPECIFICAR, SIN ESPECIFICAR, SIN ESPECIFICAR, roberto.alvarez@uneatlantico.es, SIN ESPECIFICAR (2023) Optimal Sizing and Power System Control of Hybrid Solar PV-Biogas Generator with Energy Storage System Power Plant. Sustainability, 15 (7). p. 5739. ISSN 2071-1050 document_url: http://repositorio.uneatlantico.es/id/eprint/17893/1/sustainability-15-05739-v3.pdf